MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Body & Paint

Glass, Frames and Mechanisms

501-11 Glass, Frames and Mechanisms

2016 MustangReference 1,227 / 6,619HTML edition
← Chapter contentsProcedure contents

Yes

For an inoperative LH or RH door window, INSTALL a new window regulator motor. REFER to: Front Door Window Regulator Motor (501-11 Glass, Frames and Mechanisms, Removal and Installation).

For an inoperative left or right rear window, INSTALL a new window regulator motor. REFER to: Rear Quarter Window Regulator Motor - Convertible (501-11 Glass, Frames and Mechanisms, Removal and Installation).

No

REPAIR the circuit.

I15 VERIFY GLOBAL OPEN FEATURE IS ENABLED IN MESSAGE CENTER

Ignition ON. Verify the global open feature (Remote Open) is enabled in the message center. REFER to the Owner's Literature.

Is the global open feature enabled in the message center?

Yes

GO to I16

No

The system is operating correctly at this time. INFORM the customer how to enable/disable the global open feature in the message center. REFER to the Owner's Literature.

I16 CHECK THE RKE (REMOTE KEYLESS ENTRY) TRANSMITTER OPERATION

Operate the RKE lock/unlock function using all of the RKE transmitters.

Does the RKE lock/unlock function operate correctly with at least one of the RKE transmitters?

Yes

GO to I17

No

To diagnose the RKE system, REFER to: Locks, Latches and Entry Systems (501-14 Handles, Locks, Latches and Entry Systems, Diagnosis and Testing).

I17 CHECK FOR CORRECT BODY CONTROL MODULE B (BCM-B) OPERATION

Ignition OFF. Disconnect and inspect all the Body Control Module B (BCM-B) connectors. Repair:

corrosion (install new connector or terminals - clean module pins) damaged or bent pins - install new terminals/pins as necessary pushed-out pins - install new pins as necessary

Reconnect the Body Control Module B (BCM-B) connectors and all previously disconnected window system connectors. Make sure they seat and latch correctly. Operate the system and determine if the concern is still present.

Is the concern still present?

Yes

CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new Body Control Module B (BCM-B). REFER to: Body Control Module B (BCMB) (419-10 Multifunction Electronic Modules, Removal and Installation).

No

The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.

The Short Drop Window Feature Does Not Operate Correctly

Refer to Wiring Diagrams Cell 100 for schematic and connector information.

Normal Operation and Fault Conditions

REFER to: Glass, Frames and Mechanisms - System Operation and Component Description (501-11 Glass, Frames and Mechanisms, Description and Operation).

Possible Causes

Door window regulator motor not initialized Wiring, terminals or connectors Door ajar switch Door window regulator motor

PINPOINT TEST J : THE SHORT DROP WINDOW FEATURE DOES NOT OPERATE CORRECTLY

J1 VERIFY THE DOOR AJAR SWITCH OPERATION

Open and close the driver door and view the interior lamps operation. Open and close the passenger door and view the interior lamps operation.

Do the interior lamps operate correctly?