DTC Fault Trigger Conditions
DTC | Description | Fault Trigger Conditions |
|---|---|---|
B1086:11 | Air Distribution Damper Motor: Circuit Short to Ground | This DTC sets when the module senses lower than expected voltage on an actuator motor circuit when voltage is applied to drive the motor, indicating a short to ground. The motor can move only in one direction. |
B1086:12 Air Distribution Damper Motor: Circuit Short to Battery | This DTC sets when the module senses higher than expected voltage on the actuator motor circuit when ground is applied to drive the motor, indicating a short to voltage. The motor can move only in one direction. | |
B1086:13 Air Distribution Damper Motor: Circuit Open | This DTC sets when the module senses no voltage on the actuator motor circuit when ground is applied to drive the motor, indicating an open circuit. The motor cannot move. | |
B11E7:12 Air Distribution Damper Position Sensor: Circuit Short to Battery | This DTC sets when the module senses greater than 5 volts on the actuator feedback circuit, indicating a short to voltage. | |
B11E7:14 Air Distribution Damper Position Sensor: Circuit Short to Ground or Open | This DTC sets when the module senses less than 1 volt on the actuator feedback circuit, indicating an open circuit or a short to ground. |
Possible Sources
Wiring, terminals or connectors Air distribution door actuator Air distribution door binding or stuck FCIM
PINPOINT TEST E : INCORRECT OR ERRATIC DIRECTION OF AIRFLOW FROM OUTLETS
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
E1 CHECK THE AIR DISTRIBUTION DOOR ACTUATOR CIRCUITS FOR A SHORT TO VOLTAGE
Ignition OFF. Disconnect In-vehicle temperature and humidity sensor C233. Disconnect Driver side temperature door actuator C2091. Disconnect Passenger side temperature door actuator C2092. Disconnect Air inlet door actuator C282. Disconnect Air distribution door actuator C232. Ignition ON. Disconnect FCIM C2402A. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C232-1 | Ground | |
C232-2 | Ground | |
C232-3 | Ground | |
C232-5 | Ground |