2016 workshop · Lighting

Turn Signal and Hazard Lamps

417-01 Exterior Lighting

2016 MustangReference 5,749 / 6,619HTML edition
← Chapter contentsProcedure contents

Description

Fault Trigger Conditions

Short to Ground

detects a short to ground from the hazard lamp function input circuit.

DTC

Possible Sources

Wiring, terminals or connectors FCIM BCM

PINPOINT TEST D : THE HAZARD LAMP FUNCTION IS INOPERATIVE OR ALWAYS ON

D1 CHECK FOR BCM (BODY CONTROL MODULE) DIAGNOSTIC TROUBLE CODES (DTCS)

Ignition ON. Using a diagnostic scan tool, perform the BCM self-test.

Is DTC B1D35:11 present?

Yes

GO to D2

No

GO to D4

D2 ISOLATE THE HAZARD FLASHER SWITCH

Ignition OFF. Disconnect: FCIM C2402B. Ignition ON. Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs) and repeat the BCM self-test.

Is DTC B1D35:11 retrieved again?

Yes

GO to D3

No

GO to D5

D3 CHECK THE HAZARD FLASHER SWITCH INPUT CIRCUIT FOR A SHORT TO GROUND

Ignition OFF. Disconnect: BCM C2280B. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2402B-20

Ground

Is the resistance greater than 10,000 ohms?

Yes

GO to D6

No

REPAIR the circuit.

D4 CHECK FOR A VOLTAGE SIGNAL TO THE HAZARD FLASHER SWITCH

Source reference 5749

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.