Yes | GO to B2 |
|---|---|
No | GO to B6 |
B2 CHECK THE EXTERIOR MIRROR UP/DOWN MOTOR
Ignition OFF. Disconnect: incorrectly operating C520 (LH exterior mirror) or C626 (RH exterior mirror). Ignition ON. Select the incorrectly operating mirror on the exterior mirror control switch. Connect:
Click to display connectors
LH exterior mirror
Lead 1 | Measurement / Action | Lead 2 |
|---|---|---|
C520-1 | C520-2 |
Click to display connectors
RH exterior mirror
Lead 1 | Measurement / Action | Lead 2 |
|---|---|---|
C626-1 | C626-2 |
Observe the test light while using the exterior mirror control switch in the up, down and released positions.
Did the test light illuminate in the up and down position and not illuminate in the released position?
Yes | GO to B10 |
|---|---|
No | GO to B3 |
B3 CHECK THE EXTERIOR MIRROR UP/DOWN CIRCUIT FOR A SHORT TO VOLTAGE
Ignition OFF. Disconnect: Front Door Window Control Switch C504. Ignition ON. Measure:
Click to display connectors
LH exterior mirror
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C520-1 | Ground |
Click to display connectors