MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Body & Paint

Pinpoint Test - DTC: AP, Convertible

501-20B Supplemental Restraint System

2016 MustangReference 2,080 / 6,619HTML edition
← Chapter contentsProcedure contents

Using a diagnostic scan tool, perform RCM self-test.

Did the on-demand DTC change from B1414:11 to B1414:93?

Yes

INSTALL a new driver door side impact sensor. REFER to: Front Door Side Impact Sensor (501-20B Supplemental Restraint System, Removal and Installation). GO to A10

No

GO to A3

A3 CHECK THE DRIVER DOOR SIDE IMPACT SENSOR FEED CIRCUIT FOR A SHORT TO GROUND AND A SHORT BETWEEN SENSOR CIRCUITS

Ignition OFF. Depower the SRS. REFER to: Supplemental Restraint System (SRS) Depowering (501-20B Supplemental Restraint System, General Procedures). Disconnect RCM C310A and C310B. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C567-1

Ground

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C567-1

C567-2

Are the resistances greater than 10,000 ohms?

A4 CHECK THE DRIVER DOOR SIDE IMPACT SENSOR AND RCM (RESTRAINTS CONTROL MODULE) CONNECTIONS (NO OPERATION INDICATED)

Ignition OFF. Depower the SRS. REFER to: Supplemental Restraint System (SRS) Depowering (501-20B Supplemental Restraint System, General Procedures). Inspect the Driver Front Door Side Impact Sensor electrical connector C567 to make sure it is fully seated and locked. Seat and lock the connector as necessary. Gain access to the RCM and inspect C310A and C310B to make sure they are fully seated and locked. Seat and lock the connector as necessary Repower the SRS. Do not prove out the SRS at this time. REFER to: Supplemental Restraint System (SRS) Repowering (501-20B Supplemental Restraint System, General Procedures). Ignition ON. Using a diagnostic scan tool, perform RCM self-test.

Source reference 2080

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.