A2 CHECK THE SYSTEM FOR ANY EVAP (EVAPORATIVE EMISSION) DTC'S

310-00C Fuel System - General Information - 5.0L

2016 Mustang5.0LReference 3,235 / 6,619HTML edition
← Chapter contents

No

GO to A2

A2 CHECK THE SYSTEM FOR ANY EVAP (EVAPORATIVE EMISSION) DTC'S

Connect the scan tool. Check the system for any EVAP DTC's.

Are any DTC's present?

Yes

Refer to Powertrain Control/Emissions Diagnosis (PC/ED) manual.

No

GO to A3

A3 MONITOR THE FTP WHILE FILLING THE FUEL TANK

NOTE: During normal fuel fill the Fuel Tank Pressure (FTP) Sensor value starts at 2.6 volts and will increase .3 to .7 of a volt from its starting point.

Monitor the Fuel Tank Pressure (FTP) reference value while filling the fuel tank. Refer to the Reference Values in the Powertrain Control/Emissions Diagnosis (PC/ED) manual. Refer to Powertrain Control/Emissions Diagnosis (PC/ED) manual.

Is FTP within specification?

Yes

GO to A5

No

GO to A4

A4 MONITOR THE FTP WHILE FILLING THE FUEL TANK WITH THE EVAP SYSTEM DISCONNECTED

Disconnect the fuel tank-to-EVAP canister quick connect coupling at the EVAP canister.

NOTE: During normal fuel fill the Fuel Tank Pressure (FTP) Sensor value starts at 2.6 volts and will increase .3 to .7 of a volt from its starting point.

Monitor the FTP reference value while filling the fuel tank. Refer to Powertrain Control/Emissions Diagnosis (PC/ED) manual.

Is FTP within specification?

Yes

INSPECT the EVAP system for blockage or restrictions. REPAIR the blockage or restriction. If the blockage or restriction cannot be repaired, INSTALL new EVAP system components.

No

GO to A5

A5 CHECK THE FUEL TANK FILLER PIPE ASSEMBLY FOR BLOCKAGE OR RESTRICTION

Remove the fuel tank filler pipe assembly. REFER to: Fuel Tank Filler Pipe (310-01C Fuel Tank and Lines - 5.0L 32V Ti-VCT, Removal and Installation). Inspect the fuel tank filler pipe and fuel tank filler pipe vent tube (if equipped) for a blockage or restriction.

Is the fuel tank filler pipe or fuel tank filler pipe vent tube (if equipped) blocked or restricted?

Yes

If possible, REPAIR the blockage or restriction. If the blockage or restriction cannot be repaired, INSTALL a new fuel tank filler pipe or fuel tank filler pipe vent tube.

Source reference 3235

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.