MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Climate Control System

Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC)

412-00 Climate Control System - General Information

2016 MustangReference 3,566 / 6,619HTML edition
← Chapter contentsProcedure contents

Positive Lead

Measurement / Action

Negative Lead

C2066-1

C2066-2

Is the voltage greater than 11 volts?

Yes

INSTALL a new blower motor. REFER to: Blower Motor (412-00 Climate Control System - General Information, Removal and Installation).

No

GO to J11

J11 CHECK THE CIRCUITS TO THE BLOWER MOTOR FOR AN OPEN

Ignition OFF. Disconnect Blower motor speed control C297. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C297-6

C2066-1

C297-5

C2066-2

Are the resistances less than 3 ohms?

Yes

GO to J12

No

REPAIR the circuit in question.

J12 CHECK THE BLOWER MOTOR CIRCUITS FOR A SHORT TOGETHER

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2066-1

C2066-2

Is the resistance greater than 10,000 ohms?

Yes

INSTALL a new blower motor speed control. REFER to: Blower Motor Speed Control (412-00 Climate Control System - General Information, Removal and Installation). TEST the system for normal operation. If the concern is still present, GO to J13

No

REPAIR the circuits.

J13 CHECK FOR CORRECT FRONT CONTROLS INTERFACE MODULE (FCIM) OPERATION

Source reference 3566

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.