Battery
Base Part Number: 10655
Special Tool(s)
GR1 190 V3.0 Intelligent Diagnostic Charger 162-00036 |
Battery Condition Test
Battery condition is determined by measuring battery terminal voltage after a specific discharge current is applied for a specified time period.
Visual Inspection and Diagnostic Pre-checks
Diagnostics in this manual assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods (100-00 General Information, Description and Operation).
Inspect wiring, terminals and connectors. Inspect the battery. Inspect the battery mounting. Inspect the BJB connections.
PINPOINT TEST A : BATTERY CONDITION TEST
A1 TEST THE BATTERY CONDITION
NOTE: The 5.2L Ti-VCT (SVT) vehicles do not have state-of-charge battery eye.
NOTE: A red state-of-charge battery eye indicates the battery is discharged, not necessarily damaged.
NOTE: Failure to fully charge the battery before retesting may cause false readings.
Using the Intelligent Diagnostic Charger and the battery cables removed from the battery, verify the battery condition.
Is the battery OK?
Yes | RETURN the battery to service. |
|---|---|
No | If the analyzer reads REPLACE BATTERY or REPLACE-BAD CELL, INSTALL a new battery. REFER to: Battery (414-01 Battery, Mounting and Cables, Removal and Installation). |
Copyright © 2016 Ford Motor Company
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.