Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2398-1 | Ground |
Is the voltage within 0.2 volts of the recorded battery voltage?
Yes | GO to AQ5 | |
|---|---|---|
No | REPAIR the circuit for high resistance. | |
AQ5 CHECK THE SUSPECT MODULE GROUND CIRCUIT FOR CONTINUITY
Measure the voltage at the suspect module. For the ACM, measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C240A-1 | C240A-13 |
For the APIM, measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-1 | C2383-37 |
For the DACMC, measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C240A-1 | C240A-13 |
For the FCIM, measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2402A-26 | C2402A-1 |
For the GPSM, measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2398-1 | C2398-6 |
Is the suspect module voltage greater than 11 volts?
Yes • For the ACM, GO to AQ6
• For the APIM, GO to AQ7