MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Powertrain Control-Emissions Diagnosis

2.3L GTDI Focus — reference values

Powertrain Control-Emissions Diagnosis

Ford gasoline diagnostic supplementReference 5,402 / 6,619HTML edition
← Chapter contentsProcedure contents

Vehicle applicability: This diagnostic supplement covers multiple Ford vehicles and engines. Follow the application named in the source below. Some references apply to vehicles other than Mustang.

6-48 Reference Values

2.3L GTDI Focus

(Continued)

Outputs Component/PID Measured/PID Values Units Only Measured/PID KOEO Hot Idle 48 KM/H (30 89 KM/H (55 MPH) MPH) FP Fuel Pump 75/ON 25.14/ON 24.74/ON 24.39/ON %/ON/OFF Control Module FUELSYS PID CLOSED LOOP CLOSED LOOP CLOSED LOOP CLOSED LOOP OPEN LOOP/ CLOSED LOOP HFC PID OFF OFF OFF OFF ON/OFF HTR11 HO2S11 Sensor OFF ON ON ON VOLTS/ON/ OFF HTR12 HO2S12 Sensor OFF ON ON ON VOLTS/ON/ OFF LFC PID OFF ON ON OFF ON/OFF LONGFT1 PID (I) -20 TO +20 -20 TO +20 -20 TO +20 % MIL PID OFF OFF OFF OFF ON/OFF O2S11_HTR HO2S11 Sensor 0 38.03 34.51 36.47 % O2_DS_ PID YES NO NO NO YES/NO DISBL RO2FT1 PID 0 0.80 1.23 1.78 % SHRTFT1 PID (I) -10 TO +10 -10 TO +10 -10 TO +10 % SPARKADV PID 10 10.50 33.00 26.50 DEG TQ_CNTRL PID NONE IDLE SPEED NONE NONE STATUS REQUESTED CONTROL REQUESTED REQUESTED TURBO_ TCBY Valve OFF OFF OFF OFF ON/OFF BPASS TURBO_ Turbocharger 10.10 10.07 43.28 89.73 % WGATE Wastegate Regulating Valve Solenoid VCT_EXH_ VCT12 Solenoid 0 0 40.14 39.32 % DC1 VCT_INT_ VCT11 Solenoid 0 0 0 0 % DC1

Original table alignment retained · Scroll horizontally if needed

Other Component/PID Measured/PID Values Units Only Measured/PID KOEO Hot Idle 48 KM/H (30 89 KM/H (55 MPH) MPH) VPWR PID VBAT VBAT VBAT VBAT VOLTS VREF PID 5 5 5 5 VOLTS

Original table alignment retained · Scroll horizontally if needed

2016 Powertrain Control/Emissions Diagnosis, Gasoline Engines, 3/2015

Source reference 5402

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.