Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C286-2 | Ground |
Is the voltage approximately 5 volts?
Yes | INSTALL a new autolamp and rain sensor or sunload sensor. REFER to: Light Sensor (417-01 Exterior Lighting, Removal and Installation). |
|---|---|
No | GO to A3 |
A3 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION
Disconnect and inspect all BCM connectors. Repair:
corrosion (install new connector or terminals – clean module pins) damaged or bent pins – install new terminals/pins pushed-out pins – install new pins as necessary
Reconnect the BCM connectors. Make sure they seat and latch correctly. Operate the system and determine if the concern is still present.
Is the concern still present?
Yes | CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Click here to access Guided Routine (BCM). |
|---|---|
No | The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues. |
The Autolamps Are On Continuously
Refer to Wiring Diagrams Cell 85 for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Exterior Lighting - System Operation and Component Description (417-01 Exterior Lighting, Description and Operation).
DTC Fault Trigger Conditions
Description | Fault Trigger Conditions | |||
|---|---|---|---|---|
DTC | ||||
B1A85:11 | Ambient Sunload Sensor: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCM detects a short to ground from the light sensor input circuit. | ||
B1A85:13 Ambient Sunload Sensor: Circuit Open | An on-demand DTC that sets when the BCM detects an open or short to voltage from the light sensor input circuit. | |||