MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Lighting

Fog Lamps

417-01 Exterior Lighting

2016 MustangReference 5,614 / 6,619HTML edition
← Chapter contentsProcedure contents

Description

Fault Trigger Conditions

DTC

B1147:15

Left Front Fog Lamps: Circuit Short To Battery or Open

A continuous memory and on-demand DTC that sets when the BCM detects an open from the LH fog lamp output circuit.

B1148:11

Right Front Fog Lamps: Circuit Short To Ground

A continuous memory and on-demand DTC that sets when the BCM detects a short to ground from the RH fog lamp output circuit.

B1148:15

Right Front Fog Lamps: Circuit Short To Battery or Open

A continuous memory and on-demand DTC that sets when the BCM detects an open from the RH fog lamp output circuit.

U1000:00 Solid State Driver

Protection Active -Driver Disabled: No Sub Type Information

This DTC sets when the BCM has temporarily shut down the output driver. The module has temporarily disabled an output because an excessive current draw exists (such as a short to ground). The BCM cannot enable the output until the cause of the short is corrected, the Diagnostic Trouble Codes (DTCs) have been cleared and a successful self-test is run.

U3000:49 Control Module: Internal

Electronic Failure

This DTC sets when the BCM has permanently shut down the output driver. The module has permanently disabled an output because an excessive current draw fault (such as a short to ground) has exceeded the limits that the BCM can withstand. CORRECT the cause of the excessive current draw before installing a new BCM.

Possible Sources

Bulb Wiring, terminals or connectors BCM

Visual Inspection and Diagnostic Pre-checks

Inspect the bulbs and make sure they are OK.

PINPOINT TEST C : AN INDIVIDUAL FRONT FOG LAMP IS INOPERATIVE

C1 CHECK FOR VOLTAGE TO THE INOPERATIVE FOG LAMP

Ignition OFF. Disconnect: Inoperative LH Fog Lamp C152 or RH Fog Lamp C162. Ignition ON. Place the headlamp switch in the PARKLAMPS position and engage the fog lamp switch. Measure:

Click to display connectors

LH Fog Lamp

Positive Lead

Measurement / Action

Negative Lead

C152-1

Ground

Click to display connectors

RH Fog Lamp

Positive Lead

Measurement / Action

Negative Lead

C162-1

Ground

Source reference 5614