MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Electrical Distribution

Communications Network

418-00 Module Communications Network

2016 MustangReference 5,870 / 6,619HTML edition
← Chapter contentsProcedure contents

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C251-6

C251-14

Is the resistance between 54 and 66 ohms?

Yes

GO to A5

No

GO to A4

A4 CHECK THE HS-CAN1 (HIGH SPEED-CONTROLLER AREA NETWORK 1) CIRCUITS BETWEEN THE PCM (POWERTRAIN CONTROL MODULE) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN

Disconnect PCM C1551B (2.3L), C1381B (3.7L) or C175B (5.0L, 5.2L). Measure:

Click to display connectors

2.3L

Positive Lead

Measurement / Action

Negative Lead

C1551B-69

C251-6

C1551B-68

C251-14

Click to display connectors

3.7L

Positive Lead

Measurement / Action

Negative Lead

C1381B-75

C251-6

C1381B-76

C251-14

Click to display connectors

5.0L or 5.2L

Positive Lead

Measurement / Action

Negative Lead

C175B-75

C251-6

C175B-76

C251-14

Are the resistances less than 3 ohms?

Yes

GO to A5

No

REPAIR the circuit in question.

Source reference 5870

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.