MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Electrical Distribution

Communications Network

418-00 Module Communications Network

2016 MustangReference 5,922 / 6,619HTML edition
← Chapter contentsProcedure contents

PINPOINT TEST AA : THE MOVEABLE ROOF CONTROL MODULE A (MRCMA) DOES NOT RESPOND

TO THE DIAGNOSTIC SCAN TOOL

AA1 CHECK THE MOVEABLE ROOF CONTROL MODULE A (MRCMA) VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

Ignition OFF. Disconnect: Moveable Roof Control Module A (MRCMA) C4830. Ignition ON. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C4830-6

Ground

Is the voltage greater than 11 volts?

Yes

GO to AA2

No

VERIFY BJB fuse 17 (20A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams manual to identify the possible causes of the circuit short.

AA2 CHECK THE MOVEABLE ROOF CONTROL MODULE A (MRCMA) GROUND CIRCUIT FOR AN OPEN

Ignition OFF. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C4830-5

Ground

Is the resistance less than 3 ohms?

Yes

GO to AA3

No

REPAIR the circuit.

AA3 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) CIRCUITS BETWEEN THE MOVEABLE ROOF CONTROL MODULE A (MRCMA) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN

Disconnect: GWM C2431. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C4830-9

C2431-23

C4830-10

C2431-22

Are the resistances less than 3 ohms?

Source reference 5922