← Chapter contentsProcedure contents

Normal Operation and Fault Conditions

The HUD module communicates with the diagnostic scan tool through the HS-CAN2.

Possible Sources

Fuse Wiring, terminals and connector HUD module

Visual Inspection and Diagnostic Pre-checks

Verify BJB fuse 66 (5A) is OK.

PINPOINT TEST Z : THE HEAD UP DISPLAY (HUD) MODULE DOES NOT RESPOND TO THE

DIAGNOSTIC SCAN TOOL

Z1 CHECK THE HUD (HEAD UP DISPLAY) MODULE VOLTAGE SUPPLY CIRCUITS FOR AN OPEN

Ignition OFF. Disconnect: HUD Module C2395. Ignition ON. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2395-4

Ground

Is the voltage greater than 11 volts?

Yes

GO to Z2

No

VERIFY the BJB fuse 66 (5A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams manual to identify the possible causes of the circuit short.

Z2 CHECK THE HUD (HEAD UP DISPLAY) MODULE GROUND CIRCUIT FOR AN OPEN

Ignition OFF. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2395-1

Ground

Is the resistance less than 3 ohms?

Yes

GO to Z3

No

REPAIR the circuit.