AC2 CHECK THE HS-CAN1 (HIGH SPEED-CONTROLLER AREA NETWORK 1) CIRCUITS BETWEEN THE GWM (GATEWAY MODULE A) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-20 (component side) | C251-6 | |
C2431-19 (component side) | C251-14 |
Are the resistances less than 3 ohms?
Yes | GO to AC3 |
|---|---|
No | GO to AC9 |
AC3 CHECK THE HS-CAN2 (HIGH SPEED-CONTROLLER AREA NETWORK 2) TERMINATION RESISTANCE
Connect: GWM C2431. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C251-3 | C251-11 |
Is the resistance between 54 and 66 ohms?
Yes | GO to AC5 |
|---|---|
No | GO to AC4 |
AC4 CHECK THE HS-CAN2 (HIGH SPEED-CONTROLLER AREA NETWORK 2) CIRCUITS BETWEEN THE GWM (GATEWAY MODULE A) AND THE DLC (DATA LINK CONNECTOR) FOR AN OPEN
Disconnect: GWM C2431. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-18 (component side) | C251-3 | |
C2431-17 (component side) | C251-11 |
Are the resistances less than 3 ohms?
Yes | GO to AC5 |
|---|---|
No | GO to AC9 |