Yes | GO to AG8 |
|---|---|
No | GO to AG7 |
AG7 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) TERMINATION RESISTOR, HARNESS SIDE
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-23 | C2431-22 |
Is the resistance between 108 and 132 ohms?
Yes | GO to AG9 |
|---|---|
No | GO to AG31 |
AG8 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) CIRCUITS BETWEEN THE FCIM AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
Disconnect: FCIM C2357A Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2357A-17 | C2431-23 | |
C2357A-18 | C2431-22 |
Are the resistances less than 3 ohms?
Yes | GO to AG30 |
|---|---|
No | REPAIR the circuit in question. |
AG9 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (+) AND MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (-) CIRCUITS FOR A SHORT TOGETHER
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-23 | C2431-22 |
Is the resistance less than 3 ohms?
Yes | GO to AG10 |
|---|
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.