No | GO to AG12 |
|---|
AG10 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (+) AND MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (-) CIRCUITS FOR A SHORT TOGETHER WITH MODULES DISCONNECTED
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-23 | C2431-22 |
Disconnect modules one at a time until the resistance is greater than 3 ohms.
APIM (if equipped) C2383 or C2342 (touchscreen display) Body Control Module B (BCMB) C4368A DDM C501A DSM C341D FCIM C2357A GPSM C2398 Moveable Roof Control Module A (MRCMA) C4830 (if equipped) Moveable Roof Control Module B (MRCMB) C4831 (if equipped) PDM C652A RTM C4458 SCME C3265C (if equipped) SODL C4369 (if equipped) SODR C4370 (if equipped)
Did the resistance change to greater than 3 ohms with one of the modules disconnected?
Yes | For the APIM, GO to AG28 For the Body Control Module (BCMB), GO to AG29 For the DDM, GO to AG32 For the DSM, GO to AG34 For the FCIM, GO to AG30 For the GPSM, GO to AG33 For the Moveable Roof Control Module A (MRCMA), GO to AG35 For the Moveable Roof Control Module B (MRCMB), GO to AG36 For the PDM, GO to AG37 For the RTM, GO to AG38 For the SCME, GO to AG39 For the SODL, GO to AG40 For the SODR, GO to AG41 | |
|---|---|---|
No | REPAIR the circuits. | |
AG11 CHECK THE MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (+) AND MS-CAN (MEDIUM SPEED-CONTROLLER AREA NETWORK) (-) CIRCUITS FOR A SHORT TO GROUND WITH THE MODULES DISCONNECTED
Measure
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-23 | Ground | |
C2431-22 | Ground |
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.