DTC | Description | Fault Trigger Conditions |
B1C09:11 | Driver Left/Right Mirror Motor: Circuit Short To Ground | This continuous and on-demand DTC sets if the DDM detects a higher than expected current draw when voltage is applied to the horizontal mirror motor circuit. |
B1C09:15 Driver Left/Right Mirror Motor: Circuit Short To Battery Or Open | This continuous and on-demand DTC sets if the DDM detects a lower than expected current draw when voltage is applied to the horizontal mirror motor circuit. | |
B1C10:11 | Driver Up/Down Mirror Motor: Circuit Short To Ground | This continuous and on-demand DTC sets if the DDM detects a higher than expected current draw when voltage is applied to the vertical mirror motor circuit. |
B1C10:15 Driver Up/Down Mirror Motor: Circuit Short To Battery Or Open | This continuous and on-demand DTC sets if the DDM detects a lower than expected current draw when voltage is applied to the vertical mirror motor circuit. | |
B1C13:11 | Driver Up/Down Mirror Motor Feedback: Circuit Short To Ground | This continuous and on-demand DTC sets if the DDM detects a short to ground on the vertical position feedback circuit. |
B1C13:15 Driver Up/Down Mirror Motor Feedback: Circuit Short To Battery Or Open | This continuous and on-demand DTC sets if the DDM detects a short to voltage or open on the vertical position feedback circuit. | |
B1C14:11 | Driver Left/Right Mirror Motor Feedback: Circuit Short To Ground | This continuous and on-demand DTC sets if the DDM detects a short to ground on the horizontal position feedback circuit. |
B1C14:15 Driver Left/Right Mirror Motor Feedback: Circuit Short To Battery Or Open | This continuous and on-demand DTC sets if the DDM detects a short to voltage or open on the horizontal position feedback circuit. | |
C1B15:11 | Sensor Supply Voltage B: Circuit Short To Ground | This continuous and on-demand DTC sets if the DDM detects a short to ground on the LH exterior mirror position sensor voltage supply circuit. |
C1B15:15 Sensor Supply Voltage B: Circuit Short To Battery or Open | This continuous and on-demand DTC sets if the DDM detects a short to voltage or open on the LH exterior mirror position sensor voltage supply circuit. |
Possible Causes
Wiring, terminals or connectors Exterior mirror control switch (integral to the front door window control switch) Exterior mirror DDM
Visual Inspection and Diagnostic Pre-Checks
Inspect BJB fuse 11 (30A).
PINPOINT TEST C : THE LH (LEFT-HAND) EXTERIOR MIRROR IS INOPERATIVE OR DOES NOT
OPERATE CORRECTLY IN ONE OR MORE DIRECTION(S) (WITH MEMORY MIRRORS)
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may cause damage to the connector. Use only Rotunda Flex Probes (NUD105-
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.