Starting System — Pinpoint Test(S) — Pinpoint Test A : Engine Does Not Crank

Starting System - 3.7L Duratec (227kW & 301PS)

Source configuration appliesSource reference 6,283HTML edition
← Chapter contentsManual collection

While holding the key in the START position, measure:

Positive Lead

Measurement / Action

Negative Lead

C197C-1 ("S" terminal)

Ground

Is the voltage greater than 11 volts?

Yes

CLEAN the starter solenoid "S" terminal and starter solenoid connector. CHECK the wiring and the starter motor for a loose or intermittent connection.

No

REPAIR the circuit for an open.

A21 CHECK THE PCM (POWERTRAIN CONTROL MODULE) STARTER RELAY CIRCUITS FOR A SHORT TO GROUND

Ignition OFF.

Disconnect BJB starter relay.

Disconnect PCM C1381B .

Measure:

Positive Lead

Measurement / Action

Negative Lead

C1381B-1

Ground

C1381B-58

Ground

Are the resistances greater than 10, 000 ohms?

Yes

GO to A22

No

REPAIR the affected circuit.

A22 CHECK THE PCM (POWERTRAIN CONTROL MODULE) STARTER RELAY CIRCUITS FOR AN OPEN

Measure:

Positive Lead

Measurement / Action

Negative Lead

C1381B-1

BJB starter relay pin 1

C1381B-58

BJB starter relay pin 2

Are the resistances less than 3 ohms?

Yes

GO to A28