Charging System - Overview

414-00 Charging System - General Information

2016 MustangReference 4,024 / 6,619HTML edition
← Chapter contentsProcedure contents

414-00 Charging System - General Information 2016 Mustang

Description and Operation Procedure revision date: 08/14/2014

Charging System - Overview

Overview

The generator is driven by the FEAD belt. When the engine is started, the generator begins to generate AC voltage which is internally converted to DC voltage. The DC voltage level is controlled by the voltage regulator (located on the rear of the generator) and is supplied to the battery.

The PCM controls the voltage regulation setpoint and communicates this information to the generator internal voltage regulator over a generator communication (GENCOM) communication circuit. The PCM receives generator load and error conditions from the generator over the generator monitor (GENMON) circuit.

This vehicle is equipped with load shed strategy. With the engine off, the BCM monitors the battery state of charge using the battery current sensor attached to the negative battery cable. With the engine running, the PCM monitors system voltage on the VPWR and PSCM.

The PCM monitors the generator current using the generator current sensor attached to the generator B+ battery cable. The information supplied to the PCM from the generator current sensor is used by the PCM to adjust the engine idle stability and torque control.