Vehicle applicability: This diagnostic supplement covers multiple Ford vehicles and engines. Follow the application named in the source below. Some references apply to vehicles other than Mustang.
( + ) TCBY Valve Connector, Component Side | ( - ) TCBY Valve Connector, Component Side |
|---|---|
TCBY | VPWR |
• For TCBY2,
• Measure the resistance between:
( + ) TCBY2 Valve Connector, Component Side | ( - ) TCBY2 Valve Connector, Component Side |
|---|---|
TCBY2 - Pin 2 | VPWR - Pin 1 |
• For turbocharger wastegate regulating valve solenoid,
• Measure the resistance between:
( + ) Turbocharger Wastegate Regulating Valve Solenoid Connector, Component Side | ( - ) Turbocharger Wastegate Regulating Valve Solenoid Connector, Component Side |
|---|---|
TCWRVS | VPWR |
Are the resistances between 5 - 60 ohms?
Yes | No |
|---|---|
GO to HN10 . | INSTALL a new component. REFER to the Workshop Manual Section 303-14, Electronic Engine Controls. Clear the PCM DTCs. REPEAT the self-test. |
HN10 CHECK THE WIRING HARNESS
Note: This step applies to multiple components, only measure the circuits that apply to the vehicle and component being diagnosed.
• Ignition OFF.
• PCM connector connected.
• For TCBY or TCBY2,
• Suspect TCBY Solenoid connector connected.
• Ignition ON, engine OFF.
• Access the PCM and monitor the TURBO_BP1_STAT (MODE) PID.
• Access the PCM and monitor the TURBO_BP2_STAT (MODE) PID.
• For the turbocharger wastegate regulating valve solenoid,
• Turbocharger Wastegate Regulating Valve Solenoid connector connected.
• Ignition ON, engine OFF.
• Access the PCM and monitor the TWGATE_STAT (MODE) PID.
• For wastegate vacuum sensor,
• Wastegate Vacuum Sensor connector connected.
• Ignition ON, engine OFF.
• Access the PCM and monitor the WGATE_PRES_F (MODE) PID.
• While observing the PID, wiggle, shake, and bend small sections of the wiring harness while working from the component to the PCM.