DTC | Description | Fault Trigger Conditions |
|---|---|---|
B1115:11 | High Mounted Stop Lamp Control: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCM detects a short to ground from the high mounted stoplamp voltage supply circuit. |
B1115:15 | High Mounted Stop Lamp Control: Circuit Short To Battery Or Open | A continuous memory and on-demand DTC that sets when the BCM detects an open or short to voltage from the high mounted stoplamp voltage supply circuit. |
B1271:11 | Left Stop/Turn Inner Lamp: Circuit Short to Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the LH inner stop/turn lamp voltage supply circuit. |
B1271:15 Left Stop/Turn Inner Lamp: Circuit Short to Battery or Open | An on-demand DTC that sets when the BCMB detects an open or short to voltage from the LH inner stop/turn lamp voltage supply circuit. | |
B1272:11 | Right Stop/Turn Inner Lamp: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the RH inner stop/turn lamp voltage supply circuit. |
B1272:15 Right Stop/Turn Inner Lamp: Circuit Short To Battery or Open | An on-demand DTC that sets when the BCMB detects an open or short to voltage from the RH inner stop/turn lamp voltage supply circuit. | |
B1273:11 | Right Stop/Turn Middle Lamp: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the RH middle stop/turn lamp voltage supply circuit. |
B1273:15 Right Stop/Turn Middle Lamp: Circuit Short To Battery or Open | An on-demand DTC that sets when the BCMB detects an open or short to voltage from the RH middle stop/turn lamp voltage supply circuit. | |
B1274:11 | Left Stop/Turn Middle Lamp: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the LH middle stop/turn lamp voltage supply circuit. |
B1274:15 Left Stop/Turn Middle Lamp: Circuit Short To Battery or Open | A continuous memory and on-demand DTC that sets when the BCMB detects an open or short to voltage from the LH middle stop/turn lamp voltage supply circuit. | |
B1275:11 | Left Stop/Turn Outer Lamp: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the LH outer stop/turn lamp voltage supply circuit. |
B1275:15 Left Stop/Turn Outer Lamp: Circuit Short To Battery or Open | An on-demand DTC that sets when the BCMB detects an open or short to voltage from the LH outer stop/turn lamp voltage supply circuit. | |
B1276:11 | Right Stop/Turn Outer Lamp: Circuit Short To Ground | A continuous memory and on-demand DTC that sets when the BCMB detects a short to ground from the RH outer stop/turn lamp voltage supply circuit. |
B1276:15 Right Stop/Turn Outer Lamp: Circuit Short To Battery or Open | An on-demand DTC that sets when the BCMB detects an open or short to voltage from the RH outer stop/turn lamp voltage supply circuit. | |
U1000:00 Solid State Driver Protection Active -Driver Disabled: No Sub Type Information | The module has temporarily disabled an output because an excessive current draw exists (such as a short to ground). The BCM or BCMB cannot enable the output until the cause of the short is corrected. ADDRESS all other Diagnostic Trouble Codes (DTCs) first. After the cause of the concern is corrected, CLEAR the Diagnostic Trouble Codes (DTCs). REPEAT the self-test. |
U3000:49 Control Module: The module has permanently disabled an output because an excessive current
Internal Electronic draw fault (such as a short to ground) has exceeded the limits that the BCM or Failure BCMB can withstand. The cause of the excessive current draw MUST be