Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C254-1 | Ground |
Is the voltage greater than 11 volts?
Yes | GO to E6 |
|---|---|
No | REPAIR the circuit. |
E6 CHECK THE GLOVE COMPARTMENT LAMP GROUND CIRCUIT FOR AN OPEN
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C254-1 | C254-2 |
Is the voltage greater than 11 volts?
Yes | INSTALL a new glove compartment lamp. |
|---|---|
No | REPAIR the circuit. |
E7 CHECK THE OVERHEAD INTERIOR LAMP VOLTAGE SUPPLY CIRCUIT FOR AN OPEN
Ignition OFF. Disconnect: Dome Lamp C901. Ignition ON. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C901-4 | Ground |
Is the voltage greater than 11 volts?
Yes | GO to E8 |
|---|---|
No | REPAIR the circuit. |
E8 CHECK THE OVERHEAD INTERIOR LAMP GROUND CIRCUIT FOR AN OPEN
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C901-4 | C901-5 |