MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Lighting

Interior Lighting

417-02 Interior Lighting

2016 MustangReference 5,836 / 6,619HTML edition
← Chapter contentsProcedure contents

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C254-1

Ground

Is the voltage greater than 11 volts?

Yes

GO to E6

No

REPAIR the circuit.

E6 CHECK THE GLOVE COMPARTMENT LAMP GROUND CIRCUIT FOR AN OPEN

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C254-1

C254-2

Is the voltage greater than 11 volts?

Yes

INSTALL a new glove compartment lamp.

No

REPAIR the circuit.

E7 CHECK THE OVERHEAD INTERIOR LAMP VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

Ignition OFF. Disconnect: Dome Lamp C901. Ignition ON. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C901-4

Ground

Is the voltage greater than 11 volts?

Yes

GO to E8

No

REPAIR the circuit.

E8 CHECK THE OVERHEAD INTERIOR LAMP GROUND CIRCUIT FOR AN OPEN

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C901-4

C901-5

Source reference 5836