Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-53 | C251-6 | |
C2383-54 | C251-14 |
Click to display connectors
Touchscreen display
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2342-53 | C251-6 | |
C2342-54 | C251-14 |
Are the resistances less than 3 ohms?
Yes | GO to O4 |
|---|---|
No | REPAIR the circuit in question. |
O4 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) CIRCUITS BETWEEN THE APIM (SYNC MODULE) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN
Disconnect GWM C2431 Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-16 | C2431-16 | |
C2383-17 | C2431-15 |
Click to display connectors
Touchscreen display
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2342-19 | C2431-16 | |
C2342-20 | C2431-15 |
Are the resistances less than 3 ohms?
Yes | If equipped with touchscreen display, GO to O5 If not equipped with touchscreen display, GO to O6 |
|---|---|
No | REPAIR the circuit in question. |