MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Electronic Feature Group

Perimeter Anti-Theft Alarm

419-01A Perimeter Anti-Theft Alarm

2016 MustangReference 5,988 / 6,619HTML edition
← Chapter contentsProcedure contents

Condition

Possible Sources

Actions

not activate from an unauthorized entry at the hood

Test

The alarm system does not activate from an unauthorized entry at a door

Door ajar input

DIAGNOSE the courtesy lamps not illuminating when a door is open. REFER to: Interior Lighting (417-02 Interior Lighting, Diagnosis and Testing).

The alarm system does not activate from an unauthorized entry at the luggage compartment lid

Luggage compartment lid ajar input

DIAGNOSE the incorrect luggage compartment lid ajar indication. REFER to: Instrumentation, Message Center and Warning Chimes (413-01 Instrumentation, Message Center and Warning Chimes, Diagnosis and Testing).

The alarm system does not activate from the intrusion sensor

Refer to the Pinpoint Test

GO to Pinpoint Test B

The alarm system does not arm or no turn signals flash confirmation

Refer to the Pinpoint Test

GO to Pinpoint Test C

No traffic horn output during alarm activation

Horn output concern

REFER to: Horn (413-06 Horn, Diagnosis and Testing).

No anti-theft alarm horn output during alarm activation

Refer to the Pinpoint Test

GO to Pinpoint Test D

The anti-theft alarm horn sounds continuously

Refer to the Pinpoint Test

GO to Pinpoint Test E

False alarm activation

Intrusion sensor input Door ajar input Hood switch input Liftgate ajar input Panic button pressed on a RKE transmitter A valid PATS key read was NOT received when the ignition transitioned to RUN

An intermittent fault exists. MONITOR the BCM alarm event Parameter Identifications (PIDs) to identify and isolate the cause of the last alarm activation.

Most Recent Alarm Trigger Event (ALARM_EVT_1) 2nd Most Recent Alarm Trigger Event (ALARM_EVT_2) 3rd Most Recent Alarm Trigger Event (ALARM_EVT_3) 4th Most Recent Alarm Trigger Event (ALARM_EVT_4)

Pinpoint Tests

The Alarm System Does Not Activate from an Unauthorized Entry at the Hood

Refer to Wiring Diagrams Cell 117 for schematic and connector information.

Normal Operations and Fault Conditions

REFER to: Perimeter Anti-Theft Alarm - System Operation and Component Description (419-01A Perimeter Anti-Theft Alarm, Description and Operation).