LH Exterior Mirror LED
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C4369-4 | C520-11 |
Click to display connectors
RH Exterior Mirror LED
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C4370-4 | C626-11 |
Is the resistance less than 3 ohms?
Yes | GO to D13 | |
|---|---|---|
No | REPAIR the circuit. | |
D9 CHECK THE EXTERIOR MIRROR BLIND SPOT INFORMATION SYSTEM (BLIS®)/CROSS TRAFFIC ALERT (CTA) LED (LIGHT EMITTING DIODE) GROUND CIRCUIT FOR AN OPEN
Measure:
Click to display connectors
LH Exterior Mirror LED
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C576-2 | Ground |
Click to display connectors
RH Exterior Mirror LED
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C676-2 | Ground |
Is the resistance less than 3 ohms?
Yes | For the LH LED, GO to D11 For the RH LED, GO to D12 |
|---|