9. If the voltage reading is still greater than 0.5 volt when checked at the "M" terminal, move the multimeter negative lead to the starter solenoid "B" terminal.
10. With the gear selector lever in Park or Neutral, engage the remote starter switch. Read and record the voltage.
11. If the voltage reading at the "B" terminal is lower than 0.5 volt, the concern is in the connections at the starter solenoid or in the solenoid contacts. Install a new starter motor.REFER to: Starter Motor .
12. If the voltage reading taken at the solenoid "B" terminal is greater than 0.5 volt after cleaning the cables and connections at the solenoid, the concern is in the positive battery cable connection or in the positive battery cable itself. Clean the positive battery cable connection. If this does not resolve the concern, install a new positive battery cable. REFER to: Battery Cables - 3.7L Duratec (227kW/301PS) .
Starter Motor - Ground Circuit Test
A slow cranking condition can be caused by resistance in the ground or return portion of the cranking circuit. This procedure checks the voltage drop in the ground circuit.
1. Connect a remote starter switch between starter solenoid "S" terminal and the battery positive terminal.
2. Connect the multimeter positive lead to the starter motor housing (the connection must be clean and free of rust or grease). Connect the negative lead to the negative battery terminal.
3. Place gear selector lever in Park or Neutral.
4. Engage the remote starter switch and crank the engine. Read and record the voltage reading. The reading should be 0.5 volt or less.