MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Climate Control System

Climate Control System - Vehicles With: Dual Automatic Temperature Control (DATC)

412-00 Climate Control System - General Information

2016 MustangReference 3,513 / 6,619HTML edition
← Chapter contentsProcedure contents

Ambient Temperature °F (°C)

Resistance ohms

-39.9°F (-40°C)

98,625 - 103,275 ohms

-4.0°F (-20°C)

28,640 - 29,600 ohms

32.0°F (°C)

9695 - 9895 ohms

68.0°F (20°C)

3675 - 3810 ohms

77.0°F (25°C)

2950 - 3050 ohms

86.0°F (30°C)

2370 - 2565 ohms

103.9°F (40°C)

1565 - 1635 ohms

Is the resistance within the specified values for the temperatures?

Yes

GO to P2

No

INSTALL a new evaporator temperature sensor. REFER to: Evaporator Temperature Sensor (412-00 Climate Control System - General Information, Removal and Installation).

P2 CHECK THE EVAPORATOR TEMPERATURE SENSOR INPUT CIRCUIT FOR A SHORT TO VOLTAGE

Ignition ON. Disconnect FCIM C2402A. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2402A-19

Ground

Is any voltage present?

Yes

REPAIR the circuit.

No

GO to P3

P3 CHECK THE EVAPORATOR TEMPERATURE SENSOR INPUT CIRCUIT FOR A SHORT TO GROUND

Connect FCIM C2402A. Ignition OFF. Disconnect FCIM C2402A. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2402A-19

Ground

Is the resistance greater than 10,000 ohms?

Source reference 3513