B1B71:11, B1B71:15
Refer to Wiring Diagrams Cell 55 for schematic and connector information.
Normal Operation and Fault Conditions
Evaporator Temperature Sensor, REFER to: Climate Control System - Vehicles With: Dual Automatic Temperature Control (DATC) - System Operation and Component Description (412-00 Climate Control System - General Information, Description and Operation).
DTC Fault Trigger Conditions
DTC | Description | Fault Trigger Conditions |
|---|---|---|
B1B71:11 | Evaporator Temperature Sensor: Circuit Short To Ground | The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground. The module defaults to calculated evaporator temperature and the compressor is shut off. |
B1B71:15 Evaporator Temperature Sensor: Circuit Short To Battery or Open | The module senses no voltage drop on the sensor reference voltage circuit, indicating a short directly to voltage or an open circuit. The module defaults to calculated evaporator temperature and the compressor is shut off. |
Possible Sources
Wiring, terminals or connectors Evaporator temperature sensor FCIM
PINPOINT TEST P : B1B71:11, B1B71:15
NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
P1 CHECK THE EVAPORATOR TEMPERATURE SENSOR RESISTANCE
Ignition OFF. Disconnect Evaporator temperature sensor C296. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C296-1 (component side) | C296-2 (component side) |
Compare the evaporator temperature sensor measured resistance with the table below.