Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C286-1 | Ground | |
C286-2 | Ground | |
C286-3 | Ground | |
C286-4 | Ground |
Is any voltage present?
Yes | REPAIR the circuit. | |
|---|---|---|
No | GO to O2 | |
O2 CHECK THE SUNLOAD SENSOR CIRCUITS FOR A SHORT TO GROUND
Ignition OFF. Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C286-1 | Ground | |
C286-2 | Ground | |
C286-3 | Ground | |
C286-4 | Ground |
Are the resistances greater than 10,000 ohms?
Yes | GO to O3 | |
|---|---|---|
No | REPAIR the circuit. | |
O3 CHECK THE SUNLOAD SENSOR SIGNAL CIRCUITS FOR AN OPEN
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C286-1 | C2402B-22 | |
C286-3 | C2402B-21 |
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C286-2 | C2280B-24 |
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.