Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-5 | Ground | |
C2383-6 | Ground |
Are the resistances greater than 10,000 ohms?
Yes | GO to S5 | |
|---|---|---|
No | REPAIR the circuit in question. | |
S5 CHECK THE MICROPHONE CIRCUITS TO THE APIM (SYNC MODULE) FOR AN OPEN
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-5 | C930-9 | |
C2383-6 | C930-10 | |
C2383-29 | C930-8 |
Are the resistances less than 3 ohms?
Yes | GO to S6 | |
|---|---|---|
No | REPAIR the circuit in question. | |
S6 CHECK THE MICROPHONE CIRCUITS TO THE APIM (SYNC MODULE) FOR A SHORT TOGETHER
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2383-5 | C2383-6 | |
C2383-5 | C2383-29 | |
C2383-6 | C2383-29 |
Is the resistance greater than 10,000 ohms?
Yes | GO to S7 | |
|---|---|---|
No | REPAIR the circuit in question. | |