Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2367-2 | Ground | |
C2367-3 | Ground | |
C2367-4 | Ground | |
C2367-5 | Ground |
Are the resistances greater than 10,000 ohms?
Yes | GO to AC8 |
|---|---|
No | INSTALL a new clockspring. REFER to: Clockspring (501-20B Supplemental Restraint System, Removal and Installation). |
AC8 CHECK THE CLOCKSPRING FOR AN OPEN
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2367-2 | C218C-5 | |
C2367-3 | C218C-7 | |
C2367-4 | C218C-10 | |
C2367-5 | C218C-8 |
Are the resistances less than 3 ohms?
Yes | GO to AC9 |
|---|---|
No | INSTALL a new clockspring. REFER to: Clockspring (501-20B Supplemental Restraint System, Removal and Installation). |
AC9 CHECK THE CLOCKSPRING FOR A SHORT TOGETHER
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2367-2 | C2367-3 | |
C2367-2 | C2367-4 | |
C2367-2 | C2367-5 | |
C2367-3 | C2367-4 | |
C2367-3 | C2367-5 | |
C2367-4 | C2367-5 |
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.