MAMUSTANG ATLASTHE ENTHUSIAST'S REFERENCE

2016 workshop · Electrical Distribution

Communications Network

418-00 Module Communications Network

2016 MustangReference 5,948 / 6,619HTML edition
← Chapter contentsProcedure contents

Yes

GO to AF3

No

GO to Pinpoint Test AE

AF3 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) TERMINATION RESISTANCE

Disconnect: GWM C2431. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2431-16

C2431-15

Is the resistance between 108 and 132 ohms?

Yes

GO to AF4

No

GO to AF6

AF4 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (+) AND HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (-) CIRCUITS FOR A SHORT TO GROUND

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2431-16

Ground

C2431-15

Ground

Are the resistances greater than 1,000 ohms?

Yes

GO to AF5

No

GO to AF11

AF5 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (+) AND HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (-) CIRCUITS FOR A SHORT TO VOLTAGE

Ignition ON. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2431-16

Ground

C2431-15

Ground

Are the voltages greater than 6 volts?

Source reference 5948