Yes | GO to AF23 | |
|---|---|---|
No | REPAIR the circuit in question. | |
AF9 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (+) AND HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (-) CIRCUITS FOR A SHORT TOGETHER
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-16 | C2431-15 |
Is the resistance less than 3 ohms?
Yes | GO to AF10 | |
|---|---|---|
No | GO to AF12 | |
AF10 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (+) AND HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (-) CIRCUITS FOR A SHORT TOGETHER WITH THE MODULES DISCONNECTED
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|---|---|
C2431-16 | C2431-15 |
Disconnect modules one at a time until the resistance is greater than 3 ohms.
APIM (if equipped) C2383 or C2342 (touchscreen display) ACM C240A DSP C2470 (if equipped) FCDIM C2123 (if equipped) IPC C220
Did the resistance change to greater than 3 ohms with one of the modules disconnected?
Yes | For the APIM, GO to AF20 For the ACM, GO to AF21 For the DSP, GO to AF22 For the FCDIM, GO to AF24 For the IPC, GO to AF23 | |
|---|---|---|
No | REPAIR the circuits in question. | |
AF11 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (+) AND HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) (-) CIRCUITS FOR A SHORT TO GROUND WITH THE MODULES DISCONNECTED
Measure:
Click to display connectors
Positive Lead | Measurement / Action | Negative Lead |
|---|
2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.