Communications Network

418-00 Module Communications Network

2016 MustangReference 5,949 / 6,619HTML edition
← Chapter contentsProcedure contents

Yes

REPAIR the circuit in question.

No

GO to AF12

AF6 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) TERMINATION RESISTOR, COMPONENT SIDE

Disconnect: GWM C2431. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2431-16 (component side)

C2431-15 (component side)

Is the resistance between 108 and 132 ohms?

Yes

GO to AF8

No

GO to AF7

AF7 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) TERMINATION RESISTOR, HARNESS SIDE

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2431-16

C2431-15

Is the resistance between 108 and 132 ohms?

Yes

GO to AF9

No

GO to AF25

AF8 CHECK THE HS-CAN3 (HIGH SPEED-CONTROLLER AREA NETWORK 3) CIRCUITS BETWEEN THE IPC (INSTRUMENT PANEL CLUSTER) AND THE GWM (GATEWAY MODULE A) FOR AN OPEN

Disconnect: IPC C220. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C220-12

C2431-16

C220-13

C2431-15

Are the resistances less than 3 ohms?

Source reference 5949