K7 CHECK FOR CORRECT FCIM (FRONT CONTROLS INTERFACE MODULE) OPERATION

Ignition OFF. Disconnect and inspect all FCIM connectors. Repair:

corrosion (install new connector or terminals – clean module pins) damaged or bent pins – install new terminals/pins pushed-out pins – install new pins as necessary

Reconnect all FCIM connectors. Make sure they seat and latch correctly. Operate the system and determine if the concern is still present.

Is the concern still present?

Yes

CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new FCIM. Refer to the appropriate section in Group 415 for the procedure.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.

B1B71:11, B1B71:15

Refer to Wiring Diagrams Cell 54 for schematic and connector information.

Normal Operation and Fault Conditions

Evaporator Temperature Sensor, REFER to: Climate Control System - Vehicles With: Electronic Manual Temperature Control (EMTC) - System Operation and Component Description (412-00 Climate Control System - General Information, Description and Operation).

DTC Fault Trigger Conditions

DTC

Description

Fault Trigger Conditions

B1B71:11

Evaporator Temperature Sensor: Circuit Short To Ground

The module senses excessive voltage drop on the sensor reference voltage circuit, indicating a short directly to ground. The module defaults to calculated evaporator temperature and the compressor is shut off.

B1B71:15 Evaporator Temperature

Sensor: Circuit Short To Battery or Open

The module senses no voltage drop on the sensor reference voltage circuit, indicating a short directly to voltage or an open circuit. The module defaults to calculated evaporator temperature and the compressor is shut off.

Possible Sources

Wiring, terminals or connectors Evaporator temperature sensor FCIM

Source reference 3570

2016 Mustang workshop publication supplied to Mustang Atlas. Original technical text and illustrations; HTML formatting by Mustang Atlas. Source page numbering is retained for traceability. Follow the configuration, revision, warnings, and cross-references in the material. About this edition.