412-00 Climate Control System - General Information

2016 MustangReference 3,572 / 6,619HTML edition
← Chapter contentsProcedure contents

No

GO to L3

L3 CHECK THE EVAPORATOR TEMPERATURE SENSOR INPUT CIRCUIT FOR A SHORT TO GROUND

Connect FCIM C2402A. Ignition OFF. Disconnect FCIM C2402A. Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2402A-19

Ground

Is the resistance greater than 10,000 ohms?

Yes

GO to L4

No

REPAIR the circuit.

L4 CHECK THE EVAPORATOR TEMPERATURE SENSOR INPUT CIRCUIT FOR AN OPEN

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C2402A-19

C296-1

Is the resistance less than 3 ohms?

Yes

GO to L5

No

REPAIR the circuit.

L5 CHECK THE EVAPORATOR TEMPERATURE SENSOR SIGNAL AND SIGNAL RETURN CIRCUITS FOR A SHORT TOGETHER

Measure:

Click to display connectors

Positive Lead

Measurement / Action

Negative Lead

C296-1

C296-2

Is the resistance greater than 10,000 ohms?

Yes

GO to L6

No

REPAIR the circuit.